eSelect-M2 series is a family of controllers using two measurement channels (+ temperature). The wide graphic display and user-friendly navigation make it a very simple and intuitive product for end-users. Predisposed for the Eatcloud connection, thanks to the “Connection Kit” (not included with the controller), the eSelect-M2 can be managed remotely. The select M is a multi-function measuring instrument featuring two (M2) measurement parameters suitable for measuring the pH, Rx (Redox), Free CHLORINE (Residual), Total CHLORINE, and Conductivity. The select M range, along with high-quality performances and advanced functions offers several characteristics that make it versatile and easy to use.

    Features of Measure and control instruments 
    1. Measures: pH, Redox (mV), Free Chlorine (ppm), Total Chlorine (ppm), Conductivity, and temperature (C°)
    2. Version pH or Redox, selectable from the user
    3. Standard versions: pH (Rx)-pH (Rx); pH (Rx)-CL; pH (Rx)-CD
    4. Timer mode, connected to auxiliary really.
    5. N.2 4-20mA outputs, programmable from the user
    6. Chlorine measure (ppm) by selective membrane sensor or aerometric cell Platinum-Copper
    7. 2 setpoints for each measure, ON/OFF mode or PWM (Pulse Width Modulation).
    8. Adjustable hysteresis on setpoint value; delay time on activation relay
    9. Alarm MAX and MIN modes on each measure.
    10. Overdosing Alarm (excessive dosing time) for each measure
    11. Timer built-in to manage the start/stop of the controller.
    12. N.2 inputs for level sensor
    13. Flow sensor input.
    14. PH and Rx can be selected on the same model by simply programming and using the related probe.
    15. Free or Total Chlorine measure may be chosen on the basis of the type of sensor used and the relative measuring range:
    16. Ion-selective membrane sensors with measure range 0-2 Cl ppm; 0-20 Cl ppm; 0-20 Cl ppm (Total);
    17. Open type amperometry cell (model CLC) with measure range 0-10 Cl ppm
    18. Timed AUX outputs programming; Adjustable timer mode; switch-on time programming.
    19. Suitable for software Eta Cloud connection; optional accessory: connectivity kit
    20. Available boxes: wall mounting (IP65)
    21. Backlighted graphic display (128x64)
    22. Start-up delay
    23. Alarm relay, NO or NC programmable from the user
    24. Automatic temperature compensation, (by PT100 probe o NTC) or manual



    Product Reviews