The "Jichai" H16V190ZLT-2 natural gas engine powers the 1100GF-T and 1200GF-T natural gas generator sets. Based on the "Jichai" 16V gas engine, this device works with both high-voltage and low-pressure gas generators. Intelligent 16-cylinder V-type high-power, high-performance natural gas engine with minimal heat consumption, great dependability, low emissions, and a long life. Natural gas engines now boast improved levels of power, economy, safety, and reliability thanks to sensible air intake system matching and the use of cutting-edge control techniques.
The control system of the 16V natural gas generator set under the "Jichai" brand utilizes the most sophisticated air-fuel ratio control system in the world, which includes the Tecjet control valve and mixer, electronic speed regulator, and WOODWARD-EGS system. Nowadays, well-known brands like Waukesha, Caterpillar, and other biogas and biogas units generally use WOODWARD control technology for their gas air intake control systems. It is very flexible in response to variations in pressure and gas concentration.
With the use of a computer interface, the intelligent, high-precision, fully computerized EGS gas air intake control system can monitor unit characteristics in real time.  The WOODWARD-ProAct actuator regulates the flow of mixed gas, allowing the engine speed to be regulated within the calibration range. A complete closed-loop electronic control system is comprised of the EGS control module and associated auxiliary equipment. using the air-fuel ratio The utilization of closed-loop control technology enhances the rationality of gas unit combustion, stability of unit operation, and precision of control.
Technical assistance
Prior to the project's implementation, technicians are dispatched to the location to measure the concentration of biogas and hydrogen sulfide, conduct a site inspection, engage in technical exchanges, and provide project plans that actually address the needs of the clients; v Engineers and technicians are dispatched to users throughout project implementation to offer a comprehensive set of equipment installation advice and on-site debugging to ensure smooth production and operation; 
Assist users in establishing pertinent operating guidelines, regulations, and rules following project implementation to guarantee timely maintenance and safe manufacturing without posing any risks to the process, as well as to establish standardized accessories. System for managing spare parts;
Technical instruction:
 

As needed, give user operation and maintenance staff on-the-job technical training in areas such as operation, maintenance, etc. User technicians can become more skilled at troubleshooting, check that the equipment is operating normally, and master equipment operation procedures thanks to the training. The length and scope of the training can be increased in accordance with the needs for general equipment failures. Both factory training and on-the-job training for manufacturing operations can be conducted at the project site.

Fuel type natural gas
Unit model 1100GF-T 1200GF-T
Rated voltage 6300V 10500V 6300V 10500V
Reference dimensions 6350×2180×25450mm (L×B×H)
Reference weight 24500kg

Technical characteristics of Natural Gas Generator Set:
1. Low-pressure gas can be used with the pre-supercharger mixing technology because gas and air are drawn into the compressor simultaneously.
2. To attain a high air-fuel ratio and accomplish lean combustion, lean combustion technology makes use of the most sophisticated gas control system in the world to precisely regulate the air-fuel ratio.
3. The air-fuel ratio (λ) can be closed-loop controlled using gas single-point injection and air-fuel ratio closed-loop control technology. To ensure that the engine runs in better condition, the engine has the ability to automatically and promptly modify the amount of gas and air to run at varied speeds and working circumstances.
4. Reliable intake and exhaust system design that makes use of large-flow superchargers and an improved high-pressure ratio to expand the intake pipe's flow area and boost intake efficiency.
5. Use German technology for high-efficiency, low-resistance intercoolers and plate oil coolers to expand the cooling area for lubricating oil and air.
6. To improve the stability and evenness of combustion in each engine cylinder, use the high-energy, high-reliability IC-16 ignition system.
7. A stable air intake system guarantees that unit power is used efficiently.
8. Robust safeguarding of the exhaust system against heat radiation and potential safety risks
9. Reasonably priced oil lubrication system to guarantee little fuel usage
10. Gas pipeline safety is guaranteed by four levels of defense Security
11. The equipment uses cutting-edge manufacturing quality control and testing procedures.