AquaEnergy Expo is a global exhibition in the water and energy field which includes a magazine, a Knowledge hub, and a virtual expo.

Menu
KROHNE VA40 Variable Area Flowmeter
(0 reviews)
Get Price
(88) Views
(0) Contacts

>= 1 pieces
$900.00

Contact Company

Pioneer Dalian Automation Instrument Co.,Ltd
Liaoning, China
(276) Views
(1) Contacts

The VA40 is a variable area (VA) flowmeter with a glass tube for measuring liquid and gas flow. The universal flowmeter is suited for all basic applications up to +100°C / +212°F and a maximum pressure of 10 bar / 145 psi. Typical applications include measuring the flow of flushing, purging, or inert gases, as well as heating and cooling circuits.
The VA40 does not require an external power supply. The measuring cone, which is protected by a metal sleeve with a viewing glass, allows for direct reading of the flow and observation of the medium. The VA meter can also have two optional limit switches (MIN/MAX) or analogue output (4...20 mA). The flowmeter includes numerous process connections and can be utilized in hazardous environments.

Type Flowmeter
Discrete outputs Limit switches
Family name VA
Positioning For basic applications
Measurement principle Variable area float
Measured media Liquids, Gases
Process pressure max. 10 barg/ 145 psig
Process temperature 0…+100°C/ +32…+212°F
Material of Measuring tube Borosilicate glass
Material of Gaskets Ethylene propylene diene monomer (EPDM), Perfluoroelastomer rubber (FFKM), Fluoroelastomer rubber (FPM), Nitrile butadiene rubber (NBR)
Process connection Austenitic stainless steel (1.4404/316L), Polyvinylidene fluoride (PVDF), Chromised steel
Flange connections EN (1092-1): DN15…50 ASME (B 16.5): ½…2"
Analogue outputs 4…20 mA
Thread connections Female: G½, G¾, G1, G1½, G2 ½ NPT, ¾ NPT, 1 NPT, 1½ NPT, 2 NPT
Certificates/Approvals Safety SIL 2
Certificates/Approvals Hygienic FDA, EC 1935/2004
Other connections Hose: DN15, DN25, DN40, DN50
Hygienic connections Clamp (DIN 32676): DN15, DN25, DN40, DN50 Clamp (ISO 2852) 17.2, 25, 40, 51 Tri-Clamp: ½", 1", 1½", 2" Threaded ferrule (DIN 11851): DN15, DN25, DN40, DN50 Threaded ferrule (SMS 1146): 25 mm, 38 mm, 51 mm
Certificates/Approvals Ex ATEX, UKEX

The following characteristics and settings are dependent on the device configuration: Please contact us to ensure that your desired functionality can be incorporated in a single device.

  1. Simple, low-cost measuring principle that does not require extra power.
  2. For direct flow reading and medium observation.
  3. MIN/MAX flow switches (SIL 2 according to IEC 61508-2) or 4...20mA for recording and control are optional.
  4. For liquids, the full scale value is 0.4...10,000 l/h / 0.1...2,650 GPH.
  5. For gases, the full scale value is 7...310,000 l/h / 0.25...11,000 SCFH.
  6. The maximum measuring error is 1% (according to VDI/VDE 3513-2) or 1% of the whole scale.
  7. The turndown ratio is 10:1.
  8. Use in high-risk regions.
  9. Suitable for use in SIL 2 Safety Instrumented Systems, redundant designs (1oo2), and SIL 3 applications (type A device).
  10. Food and pharmaceutical versions are available (with FDA-compliant components).

Product Reviews
You must Login/Register to can submit your review

All Rights Reserved to AquaEnergy Expo © 2024