Commercial Reverse Osmosis Water Purification Systems are used to purify water. This system consists of a booster pump, FRP pretreatment tanks (sand filter, activated carbon filter), SS304 cartridge filter housing, chemical dosing systems, a high-pressure pump, FRP membrane pressure vessel, 4040 membranes, a control panel, and touch screen control.
Material and parts brands can be changed as regards raw water quality and customer demand.
From the touch screen panel, you can see all system flow diagrams and automatic or manual control of the system. You manage all systems with our new water treatment technologies.
Membranes do not allow small particles, viruses, or bacteria to pass as a result your water becomes very clean and safe.
Chunke as a Water Purification System producer in the water treatment industry has made a lot of projects for RO water treatment systems. Our systems are purifying a million liters of water in high quality, and it makes us a leader in the water treatment industry. Chunke always uses new water treatment technologies in our projects.
Commercial reverse osmosis water treatment system capacity range between 2m3/day to 38m3/day. If you need bigger than this capacity please see our industrial reverse osmosis system.
All commercial reverse osmosis water treatment systems and industrial reverse osmosis systems are started from a booster pump, which feeds raw water to pretreatment tanks. Depending on capacity pretreatment tank size and numbers can be changed. Also depending on the raw water source and TDS (Total Dissolved Solid) material can be changed. In Chunky if the water source is Tap or low TDS fresh water, we can use FRP, Stainless Steel 304, or 316. If salt content and TDS are high, because of the corrosion, we are using FRP or Carbon Steel material for pretreatment tanks. Pretreatment consists of Sand Media Filter Tank, Activated Carbon Filter Media Tank, and Softener Tank which has ion exchange resin inside, they are very important for commercial & industrial reverse osmosis systems.
Pretreatment is used to remove a large number of suspended solids, iron, turbidity, unwanted color, unpleasant taste, chlorine, sediment, organic contaminants, and odors. In pretreatment, we can control the following manual or automatic for commercial water purification plants.
After pretreatment water goes to the cartridge filter housing, which we call a security filter, For most of the applications we are using stainless steel 304 or 316 material, but if water is very salty like brackish or seawater, we can use carbon steel or FRP or PVC Plastic Cartridge Filter Housing or Bag Filter Housing. There is a 1µm or 5 µm PP filter in the cartridge filter housing at the commercial water treatment system.
After the cartridge filter housing, water goes to the membrane pressure vessel with a High-Pressure Pump, you have a brand option for a High-Pressure Pump and it allows you to adjust your budget. The membrane housing shell inside depends on capacity we have 4040 Membranes. For most of our projects, we are using DOW Filmtec, Toray, Vontron, Hydranautics, and LG brands. They are well-known brands in the water treatment industry.
Membranes, in Commercial RO Water Treatment Systems, are the most important part. They block if the size of the part is bigger than 0.001µm and the molecular weight is up to 150-250Dalton. It consists of impurities, particles, sugars, proteins, bacteria, dyes, and organic and inorganic solids.
Also, Commercial RO Water Treatment Systems can have chemical dosing at pretreatment or post-treatment, like anti-scaling (antiscalant), antifouling, pH adjustment, Sterilization & Disinfection chemicals. We follow the water treatment industry very closely and add new water technologies into our RO water plant.
In Chunky when we check customer water analysis reports, sometimes because of scaling and fouling problems, we can use CIP (Clean in Place) System, which washes the membrane in membrane housing and makes the membrane life longer. It is new water treatment technology for most of the applications in the water treatment industry.
Electrical Power of Commercial RO Water Treatment Systems
For commercial water purification plant needs 220-380V/50Hz/60Hz. For bigger capacity especially for industrial reverse osmosis systems, because of the high-pressure pump, it needs 380V 50/60Hz. As regards your commercial reverse osmosis water filtration machine design, we will check your electrical supply and decide to fix the power for you. Also, we have some energy-saving methods to reduce electric costs, Chunke new water treatment technologies help you to reduce your biggest cost for running the system.
 Membrane numbers and size for Commercial RO Water Treatment System
Model Number 
Permeate Flow Rate 
 Membranes 
Liter/Hour 
Size 
Quantity 
CK-RO-100L 
100 
4021 
1 
 
CK-RO-250L 
250 
4040 
1 
 
CK-RO-500L 
500 
4040 
2 
CK-RO-1000L 
1000 
4040 
4 
CK-RO-2000L 
2000 
4040 
8 

Before Buying Commercial Water Purification System, you should know:
1. Pure Water Production Capacity (L/day, L/Hour, GPD).
2. Feed Water TDS and Raw Water Analysis Report (prevent fouling and scaling problems)
3. Iron and Manganese must be removed before raw water enters the reverse osmosis water filtration membrane
4. TSS (Total Suspended Solid) must remove before the commercial water purification system’s membrane.
5. SDI (Silt Density Index) must be less than 3
6. Must be sure your water source does not have oil and grease
7. Chlorine must be removed before the commercial water treatment system
8. Available electrical power voltage and phase
9. Layout of place for commercial RO reverse osmosis system
 

Hardness over 18ppm Needs Antiscalant dosing
Feed Water TDS 0 - 1000ppm
Max. Silica Tolerance 60ppm
Max. Feed Water Temp 42°C
Turbidity Must Be Removed
Operate at Higher TDS Results Lower Recovery
Feed Water Pressure 1.5 to 6 bar
H2S Must Be Removed
Max. Iron Content 0.05ppm
Max. Feed Water Temp 42°C
pH tolerance 3-11

Applications of Commercial RO Systems
  1. Used to purify water

Standard Filters 
Available Options 
Programmable PLC Control 
Automatic Flush  
Motor Starter  
Ozone Generator 
Raw Water Feeding/Booster Pump 
UV Sterilizer 
Stainless Steel Cartridge Filter Housing 
Chemical Dosing 
FRP Membrane Housing 
pH control monitor 
Mitsibushi Processor Control 
ORP Control monitor 
Low-Pressure Switch 
Remote Control 
High-Pressure Switch 
Pretreatment System 
Liquid-filled pressure gauge 
Post Deionization Unit 
Stainless Steel 304 Frame 
CIP Membrane cleaning system 
Permeate Conductivity Monitor 
Touch Screen Control 
Raw Water Conductivity Monitor 
Tank Level Switch 
Membranes 
Customer Logo 
Control Valves 
 
 
Stainless Steel/UPVC Piping 
 
 